Bộ Ghi Dữ Liệu - Recorder model PHU, EDS10-79b

0
Hãng sản xuất :
Warranty :
Mode : PHU, EDS10-79b
Code : GE1-01862
Price : Call
Category : Other Instrumentation, Equipments
Size :
Range :
Views : 3406
Date update : 19/11/2011
Quantity :     
 

Mô tả sản phẩm

Bộ Ghi Dữ Liệu - Recorder model PHU, EDS10-79b

Model : PHU, EDS10-79b
Manufacturer : FUJI ELECTRIC
Origin : JAPAN

 

 

 

Input    system

Number    of    input    points:
  9, 18, 27 or 36 points (Can be selected at the time of purchase)

Input    circuit:     Input mutual isolation (See ”Others” on page 4 for the withstand voltage)

  Resistance bulb measured current:
    about. 1 mA

Measuring    cycles:
  9 or 18 points….100ms cycles
  27 or 36 points….200ms cycles

Recording    cycle:    1 second to 12 hours

Input    types:     Thermocouple, resistance bulb, DC voltage, and DC current (Shunt resistors are fitted in input terminals).
Note)  Provide a shunt resistor (type: PHZP0101) separately.

Measuring    range

Selection    of    input    types:
  By key operation on the front panel. Note that the same input type (thermocouple, resistance bulb, voltage) should be set ev-ery 2 channels. Refer to "Setting method of input types" for details.

Burn-out    function:
  Provided as standard for thermocouple and resistance bulb inputs.  If the input has been open-circuited, the recording level swings over 100%.

  Thermocouple burn-out current: approx. 0.2 µA

Input    filter    function:
  Settable for each channel (primary delay filter)
  Time constants are settable in the range from 0 to 900 sec.

Scaling    function:     Possible by DC voltage (current) input
  Scaling range: -32767 to 32767
  Decimal position:
    settable at any point
Unit symbol:  Selectable out of 125 different units or 12 user units of up to 7 characters.

Subtraction    function:
  Subtraction between each channel is allowed.

Totalizing    function:
  The measured value of each channel can be totalized. Applicable to daily, monthly, annual or external input totalizing.

F    value    calculation    function:
  F value (extinction value of bacteria by sterilization by heating) can be calculated from the measured temperature by each channel.

Square    rooter    function:
  Square rooter can be performed against the input value per each channel.

Computation    function:
  The following calculation is available with the computation function.

  (1) Computation function:
Addition, subtraction, multiplication, division, absolute value, exponential, square-root extraction, LOG, LN, EXP, humidity, maximum, minimum, aver-age, and integration.

  (2) Computation input enable:
Analog input (Ch1 to 72), integration input (Ch1 to 72), DI (DI1 to 16), communication input (No.1 to 36), and constant number (No.1 to 60).


Indication    system

Indicator:     12” TFT color LCD (800 x 600 dots) with backlight, no contrast adjustment.
  On the LCD, certain picture elements remain lit or extinguished.  On account of the nature inherent to LCD, the brightness may be non-uniform.  But, such are not troubles.

Color    of    indication:
  14 colors

Applicable    language:
  English, French (switchable)

Life    of    backlight:    50,000 hours in terms of total lighting time. (Replace the backlight as a set of display unit.  If the LCD extinguishing function is resorted to, the LCD can be used longer as much.)

Trend    display:     Direction: vertical and horizontal
  Number of channels: 10, 6 or 4 channels per screen group.  (Input: 72 points at the maximum).

  Display refreshment cycles:select from 1 second to 12 hours. Scale display or no-display can be se-lected.

Bar    graph    display:
  Number of channels: 10, 6 or 4 channels per screen group.  (Input: 72 points at the maximum).

  Display refreshment cycles: 1 second
Analog    meter    display:   

  Number of channels: 10, 6 or 4 channels per screen group.  Display in bar graphs or in analog meters can be selected.

  Display refresh cycle: 1 second

Digital    display:     Number of channels: 10, 6 or 4 channels per screen group.  (Input: 72 points
at the maximum).

  Display refreshment cycles: 1 second

Totalizing    data    display:
  Number of channels: 10, 6 or 4 channels per screen group.  (Input: 72 points at the maximum).
  Display refresh cycle: 1 second

Event    summary    display:
  Alarm summary and message summary can be displayed.  The message occurrence information and message display can be switched.

Ethernet    log    display:
  E-mail sending, FTP server log in/off and MODBUS TCP/IP communication start/stop can be displayed.

Parameter    display/set:
  Already-set Data Display and Set Change Display screen

TAG    indication:     Number of characters to be displayed:
  Up to 8 characters
Up to 8 characters (Note 1) at 10 or 6 channel display.
Up to 16 characters at 4 channel dis-play.
Note 1: Up to 7 characters only can be
displayed on certain screens.

Characters to be displayed:
Alphanumerics
  Tag, uni t and channel No. display:  
Which can be displayed depends on the particular screen.  Refer to the table below.
(Keywords only are extracted.)

Historical    trend    display:
  Displays past recording data read from compact flash, currently recording data or just recorded data.  The recording chart can be scrolled or, via time designation, the control can jump to an arbitrary recording chart.
Number    of    screen    groups:
  8 groups (Up to 10 channels per 1 group can be registered.)

Keyboard
No.    of    Keys:     8
Function:     Use to select various screens and set
various parameters.
Recording    function

External    memory    media:
  Compact Flash card
  Format according to FAT16 or FAT.  Otherwise, reading and saving are impos-sible.

Recording    capacity:
  1 GB maximum (compact flash).  Limiting the recording file to 64 MB is recom-mended (for 112 hours if display refresh cycle is 1 second.  See Table 1 (p. 6).)  If impossible, up to 256 MB is tolerated.  A file recorded beyond could not be opened.

  * Please change the compact flash every six month to prevent the data losing.

Recording    method:
  Turning ON the REC key allows measured data to be written at fixed cycles.
  Recorded as a new file whenever the recording starts.

Data    save    cycles:
  Linked to the display refreshment cycles on the ”Real Time Trend” screen.  How-ever, they are automatically set to about 1 minute if the refreshment cycles are set to less than 1 minute.

Trend    data:     Measurement data sampled at measurement cycle is saved in terms of mean value, instantaneous value or maximum/minimum value.

Event    data:     Saves alarm data and message data.
  Further saves power ON and OFF, if any, after starting recording.

Totalizing    value    data:
  Total izing value data at designated timing is recorded per channel .
Totalized value data at designated totalized value recording cycle or the sum total is recorded in the totalizing file. You can choose which type you want to record.
For each cahnnel. it can be select as totalizing action from Analog input to-talization, Digital input count or period of Digital input ON, and it can be select as totalizing period type from Dairy, Weekly, Monthly, Annual , Periodic, Dairy (time set) or External input signal. Even if a power failure occues during totalization and then the power is restored,the totalization restarts from the value before power failure.

Configuration    data:   
  Configuration data can be saved.  And this data can also download to recorder.

Storage    capacity    :
  Approximately 3 years when the display refresh cycle is 30 seconds (in case of 9-channel recording in ASCII data format, and 512 MB compact flash used). Refer to Table 1.

Residual    capacity    of    memory:
  Indicates how much of the memory card has been used on the screen.  If the residual capacity is none, the recording stops.

Compact    flash    card    form:    PHZP1301-512
(CF    card)     (If a card other than the above is used, no operation assurance is ensured. Meanwhile, as for other CF cards for which operation check will have been completed, the results will be posted on our company's homepage sequentially. Please refer to this website.)

Data    format:     Either of ASCII or binary format can be selected. (Switching cannot be made while the recording is in progress. In the case of ASCII format, the data can be directly read on Excel, etc.  The data recorded in binary format cannot be read directly.)

  Approximately 166 bytes per sampling for maximum/minimum recording of 9-channel input in ASCII format, or approximately 40 bytes for maximum/minimum recording of 9-channel input in binary format.

Alarm    function
No.    of    settings:     Up to 4 alarms for each channel are set-
table.

Type    of    alarm:     High/Low limits

Indication:     Status (alarm types) is displayed on digital display unit when an alarm oc-curs.
  Historical display on alarm summary (Alarm start/cancel time and alarm types)

Hysteresis:     Set within the recording range of 0 to 100%

  Acts on high or low limit alarm, and does not affect the battery alarm nor memory full alarm.

Relay    output:     Number of points; 20 (option: Up to 2 cards with relay output can be mounted.)

Transistor    output    (open    collector    output):    16 points (option)

Alarm    latch    function:   
  Holds alarm indication and alarm output even after measurement value has left the alarm range.
  ON/OFF operation is performed according to key setting.

Power    supply
Rated    power    voltage: 100 to 240V AC
    
Range    of    operating    voltage: 90 to 264V AC
    
Supply    frequency: 50/60Hz ±2% (both employable)
Power    consumption

Power voltage Consumption
100V AC About 65VA
240V AC About 80VA

 

 

 

Structure

Mounting    method:
Panel-mounted (vertical panel)

Thickness    of    panel: 2 to 26 mm

Materials:
     Stainless steel for case, PC-ABS for bezel

Color: 
    Silver for case, Munsell N2.0 (black) for bezel

External    dimensions:

300 (W) × 300 (H) × 220.5 (D) mm
Mass:     About 4.7 kg (9-point input, without option)
About 6.4 kg (full option)
External    terminal    board:
Input terminal: M3 screw terminal
Power terminal: M4 screw terminal

Operating    condition
Power    supply    voltage:
  90 to 264V AC

Power    supply    frequency:
  50/60Hz ±2% (sharing)

Ambient    temperature:
  Without Ethernet function: 0    to    50°C*1
  With Ethernet function: 0    to    40°C*2

Ambient    humidity:
  20 to 80%RH

Vibration:     10 to 60Hz  0.2m/s2
 or less

Shock:     None

Magnetic    field:     400 A/m or less

Signal    source    resistance:
  Thermocouple input .… 1kΩ or less
  Resistance bulb input .… 10Ω/wire or less (resistance of each wire of 3-wire system should be balanced).
  Voltage input .… 0.1% or less of input resistance

Mounting    posture:
  Forward tilt 0, backward tilt within 30,
horizontal 0
Warm-up    time:     One hour or more after power ON
*1:  In case of the 12th digit of ordering code is ”Y”.
*2:  In case of the 12th digit of ordering code is ”E”.
Reference    standard


Accuracy/resolution:
  Measuring conditions (23±2˚C, 65±10% RH, power voltage, frequency fluctuation within ±1%, no external noise, warm-up time of 1 hour or more, vertical mounting, standard values of signal source resistance and wiring resistance... within 1% )

Note 1) Digital indication accuracy is a percentage (%) with respect to
 input range of 1 page.
Note 2) No error of reference contact compensation of thermocouple is
 included.
Ni100
Cu50
0.1°C


Error    of    reference    contact    compensation:
  K, E, J, T, N, L, U, PN: ±0.5˚C
  R, S, B, W: ±1.0˚C
  (when measured at 0˚C or more)
Max.    input    voltage:
  Thermocouple, resistance bulb,  
DC voltage: ±10V DC (continuous)
Input    impedance:     Thermocouple,  
DC voltage:    About 1MΩ

------------------------------------------------------------------------------------------------------------------------------------